Global Thermoelectric’s Model 1500 Thermoelectric Generator is Class 1, Div II Hazardous area rated. With no moving parts, it is a reliable, low maintenance source of DC electrical power for any application where regular utilities are unavailable or unreliable.
Power Specifiations
Power Rating at 20ºC
500 Watts at 24 volts
Electrical
Adjustment: 24 V 24 - 30 Volts
Reverse current protection included.
Output: Terminal block which accepts up to 00 AWG wire. Opening for
two 3/4” conduit in the base of the cabinet.
Fuel
Natural Gas: 48.0 m3/day (1695 Sft3/day)
1000 BTU/Sft3 (37.7 MJ/SM3) gas
max 115 mg/Sm3 (~170 ppm) H2S
max 120 mg/Sm3 H2O
max 1% free O2
Propane: n/a at this time
Max. Supply Pressure: 172 kPa (25 psi)
Min. Supply Pressure: 103 kPa (15 psi)
Fuel Connection: 1/4” MNPT
Environmental
Ambient Operation Temperature: Max. 45ºC (115ºF) Min. -40ºC (-40ºF).
Operating Conditions: Unsheltered operation
Please contact Global for operating conditions below -40ºC or above +45ºC.
Materials of Construction
Cabinet: 316 SS
Cooling Type: Natural Convection
Fuel System: Aluminum & Stainless Steel
Standard Features
• Automatic Spark Ignition (SI)
• Automatic Fuel Shut-off (SO)
• Fuel Filter
• Low Voltage Alarm Contacts (VSR)
• CSA Certification
- Class 1, Div II, Group D, Temp T3
Note:
Specifications shown are for standard configurations. Global Thermoelectric’s Integrated Systems Engineering Department is available to design custom voltages, fuel supply systems and non-standard operating temperatures.